Schneider MCB 10A 1P A9K24110

Description

Schneider MCB 10A 1P A9K24110 circuit breaker is an option within the MCB automatic circuit breakers at Bashiti Stores, designed to protect the circuit from overloads and short circuits. In this version, the rated current is 10 Amperes and the number of poles is 1P. These specifications distinguish this model from other alternatives in the same series; match them with your circuit requirements and do not choose a higher amperage breaker just to increase the operating margin.

Practical Benefits

  • Combines the functions of overload and short-circuit protection in a single modular device.
  • Distributing protection across independent circuits helps organize the distribution board and identify the affected circuit in case of a fault.
  • Choosing the correct current, number of poles, and tripping curve provides the basis for matching the breaker to the circuit's requirements.

Technical Specifications for this Model

Brand Schneider Electric
Series Acti9 iK60N
Model Reference A9K24110
Rated Current 10 A
Number of Poles 1P
Tripping Curve C
Breaking Capacity (as per source title) 6kA
Stated Operating Voltage 230VAC
Dimensions: W x H x D 18 x 85 x 78.5 mm
Stated Mounting DIN Rail

Who Needs This Product?

Electricians, installation contractors, and homeowners or shop owners who are setting up a new distribution board or replacing a breaker matching an existing circuit. The choice depends on the circuit design, cable cross-section, and installation method, rather than solely on the device type or the appearance of the breaker.

Installation and Verification Procedure — For Licensed Technicians

The following steps outline the general workflow. Refer to the manufacturer's datasheet for reference A9K24110 to determine terminals and torque values. Do not perform work on a circuit connected to a power supply.

  1. The technician disconnects all power sources, secures them against accidental reconnection, and verifies the absence of voltage with a suitable tool.
  2. Matches the device reference, number of poles, current, and voltage with the board diagram, and reviews the conductor cross-section and protection coordination.
  3. Mounts the device on the rail or its designated position after ensuring compatibility, and identifies the supply and output based on the manufacturer's diagram for this reference.
  4. Executes the connections using the tightening torque, stripping length, and wire cross-sections specified in the model manual; do not carry these values over from a similar device.
  5. Inspects the security of the mounting and connections, closes the covers, and conducts the required operational and protection tests before handing over the circuit.

Frequently Asked Questions Before Purchasing

Does this breaker protect against earth leakage?

An MCB is intended for overload and short-circuit protection and does not replace earth leakage protection. The need for an RCCB or RCBO should be reviewed within the board design.

Should I replace a frequently tripping breaker with one of a higher amperage?

No. You must first identify the cause of the tripping and inspect the load, cable, and connections. Increasing the amperage without proper study may leave the wires without appropriate protection.

What is the difference between current (Amperes) and breaking capacity?

The current rating is the nominal operating current of the breaker, while the breaking capacity describes the level of short-circuit current it can safely interrupt under defined voltage and standard conditions. One should not be substituted for the other.

Order from Bashiti Stores

Discover more in the Electrical Installations and Electrical Circuit Breakers sections. Bashiti Stores — Yousef Bashiti Company, serving individuals, companies, and projects in Jordan. For inquiries about the product and quantities, contact 0795756898 or visit our Bayader and Wehdat branches in Amman.

For Comparison Within the Category

Also, check out the Schneider MCB 16A 1P A9K24116 and compare specifications to choose what suits your needs.

Schneider MCB 10A 1P A9K24110

Product form

Schneider MCB 10A 1P A9K24110 circuit breaker is an option within the MCB automatic circuit breakers at Bashiti Stores, designed... Read more

SKU: 00201106

4.200 JD

    Description

    Schneider MCB 10A 1P A9K24110 circuit breaker is an option within the MCB automatic circuit breakers at Bashiti Stores, designed to protect the circuit from overloads and short circuits. In this version, the rated current is 10 Amperes and the number of poles is 1P. These specifications distinguish this model from other alternatives in the same series; match them with your circuit requirements and do not choose a higher amperage breaker just to increase the operating margin.

    Practical Benefits

    • Combines the functions of overload and short-circuit protection in a single modular device.
    • Distributing protection across independent circuits helps organize the distribution board and identify the affected circuit in case of a fault.
    • Choosing the correct current, number of poles, and tripping curve provides the basis for matching the breaker to the circuit's requirements.

    Technical Specifications for this Model

    Brand Schneider Electric
    Series Acti9 iK60N
    Model Reference A9K24110
    Rated Current 10 A
    Number of Poles 1P
    Tripping Curve C
    Breaking Capacity (as per source title) 6kA
    Stated Operating Voltage 230VAC
    Dimensions: W x H x D 18 x 85 x 78.5 mm
    Stated Mounting DIN Rail

    Who Needs This Product?

    Electricians, installation contractors, and homeowners or shop owners who are setting up a new distribution board or replacing a breaker matching an existing circuit. The choice depends on the circuit design, cable cross-section, and installation method, rather than solely on the device type or the appearance of the breaker.

    Installation and Verification Procedure — For Licensed Technicians

    The following steps outline the general workflow. Refer to the manufacturer's datasheet for reference A9K24110 to determine terminals and torque values. Do not perform work on a circuit connected to a power supply.

    1. The technician disconnects all power sources, secures them against accidental reconnection, and verifies the absence of voltage with a suitable tool.
    2. Matches the device reference, number of poles, current, and voltage with the board diagram, and reviews the conductor cross-section and protection coordination.
    3. Mounts the device on the rail or its designated position after ensuring compatibility, and identifies the supply and output based on the manufacturer's diagram for this reference.
    4. Executes the connections using the tightening torque, stripping length, and wire cross-sections specified in the model manual; do not carry these values over from a similar device.
    5. Inspects the security of the mounting and connections, closes the covers, and conducts the required operational and protection tests before handing over the circuit.

    Frequently Asked Questions Before Purchasing

    Does this breaker protect against earth leakage?

    An MCB is intended for overload and short-circuit protection and does not replace earth leakage protection. The need for an RCCB or RCBO should be reviewed within the board design.

    Should I replace a frequently tripping breaker with one of a higher amperage?

    No. You must first identify the cause of the tripping and inspect the load, cable, and connections. Increasing the amperage without proper study may leave the wires without appropriate protection.

    What is the difference between current (Amperes) and breaking capacity?

    The current rating is the nominal operating current of the breaker, while the breaking capacity describes the level of short-circuit current it can safely interrupt under defined voltage and standard conditions. One should not be substituted for the other.

    Order from Bashiti Stores

    Discover more in the Electrical Installations and Electrical Circuit Breakers sections. Bashiti Stores — Yousef Bashiti Company, serving individuals, companies, and projects in Jordan. For inquiries about the product and quantities, contact 0795756898 or visit our Bayader and Wehdat branches in Amman.

    For Comparison Within the Category

    Also, check out the Schneider MCB 16A 1P A9K24116 and compare specifications to choose what suits your needs.

    Send us a message!

    Do you want to order the product in bulk for a company?

    Sign up for our newsletter

    Get the best deals

    Don't hesitate to subscribe to receive all offers via email

    © 2026 Bashiti Stores, Powered by Shopify

      Login

      Forgot your password?

      Don't have an account yet?
      Create account