Schneider MCB 16A 1P A9K24116 circuit breaker is an option within the MCB automatic circuit breaker range at Bashiti Stores, designed to protect the circuit against overloads and short circuits. In this version, the rated current is 16 amps and the number of poles is 1P. These specifications distinguish this model from other alternatives in the same series; match them with your circuit requirements and do not choose a higher amperage breaker just to increase the operating margin.
Practical Benefits
- Combines the functions of overload and short-circuit protection in a single modular device.
- Distributing protection across independent circuits helps organize the distribution board and identify the affected circuit when a fault occurs.
- Selecting the correct current, number of poles, and tripping curve provides the basis for aligning the breaker with circuit requirements.
Technical Specifications for this Model
| Brand |
Schneider Electric |
| Series |
Acti9 iK60N |
| Model Reference |
A9K24116 |
| Rated Current |
16 A |
| Number of Poles |
1P |
| Tripping Curve |
C |
| Breaking Capacity as per source title |
6kA |
| Rated Operating Voltage |
230VAC |
| Dimensions: W × H × D |
18 × 85 × 78.5 mm |
| Mounting |
DIN rail |
Who needs this product?
Electricians, electrical contractors, homeowners, and shop owners who are setting up a new distribution board or replacing a breaker that matches an existing circuit. Selection depends on the circuit design, cable cross-section, and installation method, not just on the device type or the breaker's appearance alone.
Installation and Verification — For Qualified Technicians
The following steps outline the general work sequence. Refer to the manufacturer's diagram for reference A9K24116 to determine terminals and torque values. Do not perform work on a live circuit.
- The technician disconnects all power sources, secures them against accidental restart, and verifies the absence of voltage with an appropriate tool.
- Verify that the device reference, number of poles, current, and voltage match the panel diagram, and check the conductor cross-section and protection coordination.
- Install the unit on the rail or its designated position after ensuring compatibility, and identify the supply and load side using the manufacturer's diagram for this reference.
- Carry out connections according to the torque, stripping length, and wire sizes specified in the model manual; do not use values from a similar device.
- Check the tightness of connections and mounting, then close covers and conduct required operational and protection tests before handing over the circuit.
Frequently Asked Questions Before Buying
Does this breaker provide earth leakage protection?
An MCB is designed for overload and short-circuit protection and does not replace the need for earth leakage protection. Check the need for an RCCB or RCBO within your panel design.
Should I replace a breaker that trips frequently with one of a higher amperage?
No. First, identify the cause of the tripping and inspect the load, cable, and connections. Increasing the amperage without proper study may leave the wires without appropriate protection.
What is the difference between Amperage and Breaking Capacity?
Amperage is the rated current of the breaker, whereas breaking capacity describes the level of short-circuit current it can safely interrupt under specified voltage and standard conditions. Do not use these numbers interchangeably.
Order from Bashiti Stores
Discover more in the Electrical Section and Circuit Breakers category. Bashiti Stores — Yousef Bashiti Co., serving individuals, companies, and projects in Jordan. For inquiries about the product and quantities, contact us at 0795756898 or visit our Bayader and Wehdat branches in Amman.
Compare Within Category
Also, check out the Schneider MCB 20A 1P A9K24120 circuit breaker, and compare specifications to choose what fits your needs.