Schneider MCB 63A 1P A9K24163 is a choice among MCB automatic circuit breakers at Bashiti Stores, designed to protect circuits from overloads and short circuits. In this model, the rated current is 63 Amps and the number of poles is 1P. These specifications distinguish the model from alternatives in the same series; match them with your circuit requirements and do not select a breaker with a higher current rating simply to increase the operating margin.
Practical Benefits
- Combines overload and short-circuit protection functions in a single modular device.
- Distributing protection across independent circuits helps organize the distribution board and identify the affected circuit in the event of a fault.
- Selecting the correct current, number of poles, and tripping curve provides the basis for matching the breaker to circuit requirements.
Technical Specifications of this Model
| Brand |
Schneider Electric |
| Series |
Acti9 iK60N |
| Model Reference |
A9K24163 |
| Rated Current |
63 A |
| Number of Poles |
1P |
| Tripping Curve |
C |
| Breaking Capacity as per source |
6kA |
| Rated Operating Voltage |
230VAC |
| Dimensions: W x H x D |
18 x 85 x 78.5 mm |
| Mounting |
DIN Rail |
Who Needs This Product?
Electricians, wiring contractors, and homeowners or shop owners who are setting up a new distribution board or replacing a breaker that matches an existing circuit. Selection depends on the circuit design, cable cross-section, and installation method, rather than just the device type or the appearance of the breaker.
Installation and Verification — For Qualified Technicians
The following steps outline the general workflow. Refer to the manufacturer's manual for reference A9K24163 to determine terminal layouts and tightening torque values. Do not perform work on a circuit connected to power.
- The technician disconnects all power sources, secures them against reconnection, and verifies the absence of voltage using appropriate tools.
- Matches the device reference, number of poles, current, and voltage with the panel diagram, and reviews conductor cross-sections and protection coordination.
- Installs the component on the rail or its designated position after ensuring compatibility, and identifies the supply and load terminals from the manufacturer's diagram for this reference.
- Performs connections according to the tightening torque, stripping length, and wire gauges specified in the model manual; do not transpose these values from a similar device.
- Checks the tightness of the installation and connections, closes the covers, and performs the required functional and protection tests before handing over the circuit.
Frequently Asked Questions Before Purchasing
Does this breaker protect against earth leakage?
An MCB is designed for overload and short circuits and does not replace earth leakage protection. The need for an RCCB or RCBO should be reviewed within the panel design.
Should I replace a breaker that trips constantly with one of a higher amperage?
No. You must first identify the cause of the tripping and inspect the load, cable, and connections. Increasing the amperage without study may leave the wires without proper protection.
What is the difference between Amperage and Breaking Capacity?
Amperage is the rated current of the breaker, while breaking capacity describes the level of short-circuit current it can interrupt under specified voltage and standard conditions. The two figures are not interchangeable.
Order from Bashiti Stores
Learn more in our Electrical Section and Circuit Breakers category. Bashiti Stores — Yousef Bashiti Co., serving individuals, companies, and projects in Jordan. For inquiries about the product and quantities, contact us at 0795756898 or visit our Bayader and Wehdat branches in Amman.
For Comparison Within the Category
Also check out the Schneider MCB 16A 2P A9K24216, and compare specifications to choose what suits your needs.