Schneider MCB 16A 2P A9K24216 is an option among the MCB automatic circuit breakers at Bashiti Stores, designed to protect circuits from overloads and short circuits. In this version, the rated current is 16 Amps and the number of poles is 2P. These specifications distinguish the model from alternatives in the same series; match them with circuit requirements and do not choose a higher-amperage breaker just to increase the operating margin.
Practical Benefits
- Combines overload and short-circuit tripping functions into a single modular device.
- Distributing protection across independent circuits helps organize the panel and identify the affected circuit in the event of a fault.
- Selecting the correct current, number of poles, and tripping curve provides a foundation for matching the breaker with circuit requirements.
Technical Specifications for This Model
| Brand |
Schneider Electric |
| Series |
Acti9 iK60N |
| Model Reference |
A9K24216 |
| Rated Current |
16 A |
| Number of Poles |
2P |
| Tripping Curve |
C |
| Breaking Capacity per Source Title |
6kA |
| Stated Operating Voltage |
230VAC |
| Dimensions: W x H x D |
36 x 85 x 78.5 mm |
| Stated Mounting |
DIN Rail |
Who Needs This Product?
Electricians, installation contractors, and homeowners or shop owners who are setting up a new panel or replacing a breaker matching an existing circuit. Selection depends on the circuit design, cable cross-section, and installation method, rather than just the device type or the appearance of the breaker.
Installation and Verification Procedure — For Professional Technicians
The following steps outline general work sequences. Refer to the manufacturer's diagram for reference A9K24216 to identify terminals and torque values. Do not perform work on a live circuit.
- The technician disconnects all power sources and secures them against accidental reconnection, then verifies the absence of voltage with a suitable tool.
- Matches the device reference, number of poles, current, and voltage with the panel diagram, and reviews conductor cross-sections and protection coordination.
- Mounts the unit on the rail or its designated position after ensuring compatibility, and identifies the supply and output from the manufacturer's diagram for this reference.
- Performs connections using the torque, stripping length, and wire sizes specified in the model manual; do not carry over these values from a similar device.
- Checks the security of mounting and connections, then closes the covers and conducts necessary functional and protection tests before handing over the circuit.
-->
Common Questions Before Buying
Does this breaker protect against earth leakage?
An MCB is intended for overloads and short circuits and does not replace earth leakage protection. Review the need for an RCCB or RCBO within the panel design.
Should I replace a breaker that trips constantly with one of a higher amperage?
No. You must first determine the cause of the tripping and check the load, cable, and connections. Increasing the amperage without assessment may leave the wires without appropriate protection.
What is the difference between current (amps) and breaking capacity?
Amps represent the rated current of the breaker, while breaking capacity describes the level of short-circuit current it can safely disconnect under specified voltage and standard conditions. Neither figure is a substitute for the other.
Order from Bashiti Stores
Learn more in our Electrical Section and Circuit Breakers category. Bashiti Stores — Yousef Bashiti Company, serving individuals, companies, and projects in Jordan. For inquiries about products and quantities, contact us at 0795756898 or visit our branches in Bayader and Al-Wehdat, Amman.
Compare Within Category
Also check out the Schneider MCB 20A 2P a9k24220 and compare specifications to choose what suits your needs.