Schneider MCB 63A 2P A9K24263 is a choice among the MCB automatic circuit breakers at Bashiti Stores, designed to protect circuits from overloads and short circuits. In this version, the rated current is 63 Amps and the number of poles is 2P. These specifications distinguish the model from other alternatives in the same series; match them with your circuit requirements and do not choose a higher amperage breaker just to increase the operating margin.
Practical Benefits
- Combines overload and short-circuit protection functions in one modular device.
- Distributing protection across independent circuits helps organize the panel and identify the affected circuit when a fault occurs.
- Choosing the correct current, number of poles, and tripping curve provides a basis for matching the breaker with the circuit requirements.
Technical Specifications for this Model
| Brand |
Schneider Electric |
| Series |
Acti9 iK60N |
| Model Reference |
A9K24263 |
| Rated Current |
63 A |
| Number of Poles |
2P |
| Tripping Curve |
C |
| Breaking Capacity per Source Title |
6kA |
| Rated Operational Voltage |
230VAC |
| Dimensions: W x H x D |
36 x 85 x 78.5 mm |
| Mounting |
DIN Rail |
Who Needs This Product?
Electricians, wiring contractors, and homeowners or shop owners who are setting up a new panel or replacing a breaker that matches an existing circuit. The choice depends on the circuit design, cable cross-section, and installation method, not just on the device type or the breaker's shape alone.
Installation and Verification — For the Professional Technician
The following steps outline the general workflow. Refer to the manufacturer's diagram for the A9K24263 reference to determine terminals and tightening values. Do not work on a circuit connected to a power supply.
- The technician disconnects all power sources and secures them against accidental restart, then verifies the absence of voltage with a suitable tool.
- Matches the device reference, number of poles, current, and voltage with the panel diagram, and reviews the conductor cross-section and protection coordination.
- Mounts the unit on the rail or its designated position after ensuring compatibility, and identifies the supply and output from the manufacturer's diagram for this reference.
- Executes connections with the tightening torque, stripping length, and wire gauges specified in the model manual; do not carry these values over from a similar device.
- Checks the tightness of the mounting and connections, closes the covers, and performs the required functional and protection tests before handing over the circuit.
-
Frequently Asked Questions Before Buying
Does this breaker protect against earth leakage?
An MCB is intended for overloads and short circuits and does not replace earth leakage protection. The need for an RCCB or RCBO should be reviewed within the panel design.
Should I replace a breaker that trips constantly with one of a higher amperage?
No. You must first identify the cause of tripping and inspect the load, cable, and connections. Increasing the amperage without study might leave the wires without appropriate protection.
What is the difference between Amperage and Breaking Capacity?
Amperage is the rated current of the breaker, while breaking capacity describes the level of short-circuit current it can disconnect under defined voltage and standard conditions. Do not substitute one for the other.