Schneider RCBO 25A 1P A9D11825 is an option within the RCBO range at Bashiti Stores, designed to combine earth leakage protection with overload and short-circuit protection for the circuit. This model features a 25-amp current rating and a 30mA leakage sensitivity. When comparing, distinguish between the current flowing through the device and the leakage value that triggers tripping, and check for the protection type appropriate for your loads.
Practical Benefits
- Combines multiple protection functions into a single device rather than relying on an overload breaker alone.
- Assigning compound protection to each appropriate circuit helps organize maintenance work and identify the affected circuit.
- The Type A classification and leakage sensitivity specify characteristics that can be matched to load requirements by a specialist.
Technical Specifications for this Model
| Brand |
Schneider Electric |
| Series |
Acti9 iC60H |
| Model Reference |
A9D11825 |
| Rated Current |
25 A |
| Number of Poles |
1P+Ns |
| Leakage Sensitivity |
30 mA |
| Leakage Detection Type |
A |
| Rated Breaking Capacity |
10,000 A |
| Rated Operational Voltage |
240VAC |
| Dimensions: W x H x D |
18 x 110 x 77.5 mm |
| Mounting |
DIN Rail |
Who Needs This Product?
Panel technicians and electrical contractors who require compound protection for an independent circuit, especially when reorganizing existing panel circuits. It is chosen based on current, leakage sensitivity, protection type, and compatibility with the installation site.
Installation and Verification — For Specialist Technicians
The following steps outline the general workflow. Refer to the manufacturer's diagram for reference A9D11825 to identify terminals and torque values. Do not work on a circuit connected to power.
- The technician disconnects all power sources, secures them against accidental restart, and verifies the absence of voltage with a suitable tool.
- Matches the device reference, number of poles, current, and voltage with the panel diagram, and checks conductor cross-sections and protection coordination.
- Mounts the unit on the DIN rail or its designated spot after confirming compatibility, and identifies the power input and output from the manufacturer's diagram for this reference.
- Executes the connections using the tightening torque, stripping length, and wire gauges specified in the model manual; do not transpose these values from a similar device.
- Checks the integrity of the mounting and connections, closes the covers, and performs the required functional and protection tests before commissioning the circuit.
-
Frequently Asked Questions Before Buying
What is the difference between an RCBO and an RCCB?
An RCBO combines leakage protection with overcurrent and short-circuit protection, whereas an RCCB requires a separate overcurrent protection device coordinated with it.
Does having a leakage breaker eliminate the need for grounding?
No. Grounding, protective bonding, and coordination of protection devices are independent parts of installation safety and are not replaced by this breaker.
Can it be installed in place of any single-pole breaker?
First, you must check dimensions, poles, neutral connection, wiring points, and the panel system. Similarity in width is not sufficient to prove compatibility.
Order from Bashiti Stores
Learn more in our Electrical Extensions and Electrical Breakers sections. Bashiti Stores — Yousef Bashiti Company, serving individuals, companies, and projects in Jordan. For inquiries about products and quantities, contact us at 0795756898 or visit our Bayader and Wahdat branches in Amman.
For comparison within the category
Also check out the Schneider RCBO 32A 1P A9D11832, and compare the specifications to choose what suits your needs.