Schneider RCBO 32A 1P A9D11832

Description

Schneider RCBO 32A 1P A9D11832 breaker is an option within the RCBO range at Bashiti Stores, designed to combine earth leakage protection with overload and short-circuit protection for the circuit. This model features a 32A current rating and 30mA leakage sensitivity. When comparing, distinguish between the current flowing through the device and the leakage value that triggers the trip, and review the appropriate protection type for the loads.

Practical Benefits

  • Combines multiple protection functions into a single device instead of relying solely on an overload breaker.
  • Assigning integrated protection to each suitable circuit helps organize maintenance and identify the affected circuit.
  • The Type A classification and leakage sensitivity clarify characteristics that can be matched to load requirements by a specialist.

Technical Specifications for this Model

Brand Schneider Electric
Series Acti9 iC60H
Model Reference A9D11832
Rated Current 32 A
Number of Poles 1P+Ns
Leakage Sensitivity 30 mA
Leakage Detection Type A
Stated Breaking Capacity 10,000 A
Stated Operating Voltage 240VAC
Dimensions: W × H × D 18 × 110 × 77.5 mm
Mounting DIN rail

Who needs this product?

Panel technicians and electrical contractors who require integrated protection for an independent circuit, especially when reorganizing circuits in an existing panel. It is chosen based on current, leakage sensitivity, protection type, and compatibility with the installation location.

Installation and Verification — For the Specialist Technician

The following steps outline the general work sequence. Refer to the manufacturer's diagram for reference A9D11832 to identify terminals and torque values. Do not perform work on a live circuit.

  1. The technician must disconnect all power sources, secure them against reactivation, and verify the absence of voltage with a suitable tool.
  2. Match the device reference, number of poles, current, and voltage with the panel diagram, and review conductor cross-sections and protection coordination.
  3. Mount the device on the rail or its designated position after ensuring compatibility, and identify input and output from the manufacturer's diagram for this reference.
  4. Execute connections using the tightening torque, stripping length, and wire gauges specified in the model manual; do not carry these values over from a similar device.
  5. Check the tightness of the installation and connections, close the covers, and conduct required functional and protection tests before handing over the circuit.

Frequently Asked Questions Before Buying

What is the difference between RCBO and RCCB?

An RCBO combines leakage protection with overcurrent and short-circuit protection, while an RCCB requires separate, coordinated overcurrent protection.

Does having a leakage breaker eliminate the need for earthing?

No. Earthing, protective bonding, and coordination of protection devices are independent parts of installation safety and are not eliminated by this breaker.

Can it be installed in place of any single breaker?

You must first review dimensions, poles, neutral, connection points, and the panel system. Similarity in width is not sufficient to prove compatibility.

Order from Bashiti Stores

Learn more in the Electrical Section and Electrical Breakers category. Bashiti Stores — Yousef Bashiti Company, serving individuals, companies, and projects in Jordan. For inquiries about the product and quantities, contact 0795756898 or visit our Bayader and Wehdat branches in Amman.

For Comparison Within the Category

Also check out the Schneider 40A 3P A9S65340 Isolation Switch, and compare the specifications to choose what fits your needs.

Schneider RCBO 32A 1P A9D11832

Product form

Schneider RCBO 32A 1P A9D11832 breaker is an option within the RCBO range at Bashiti Stores, designed to combine earth... Read more

SKU: 00201599

48.880 JD

    Description

    Schneider RCBO 32A 1P A9D11832 breaker is an option within the RCBO range at Bashiti Stores, designed to combine earth leakage protection with overload and short-circuit protection for the circuit. This model features a 32A current rating and 30mA leakage sensitivity. When comparing, distinguish between the current flowing through the device and the leakage value that triggers the trip, and review the appropriate protection type for the loads.

    Practical Benefits

    • Combines multiple protection functions into a single device instead of relying solely on an overload breaker.
    • Assigning integrated protection to each suitable circuit helps organize maintenance and identify the affected circuit.
    • The Type A classification and leakage sensitivity clarify characteristics that can be matched to load requirements by a specialist.

    Technical Specifications for this Model

    Brand Schneider Electric
    Series Acti9 iC60H
    Model Reference A9D11832
    Rated Current 32 A
    Number of Poles 1P+Ns
    Leakage Sensitivity 30 mA
    Leakage Detection Type A
    Stated Breaking Capacity 10,000 A
    Stated Operating Voltage 240VAC
    Dimensions: W × H × D 18 × 110 × 77.5 mm
    Mounting DIN rail

    Who needs this product?

    Panel technicians and electrical contractors who require integrated protection for an independent circuit, especially when reorganizing circuits in an existing panel. It is chosen based on current, leakage sensitivity, protection type, and compatibility with the installation location.

    Installation and Verification — For the Specialist Technician

    The following steps outline the general work sequence. Refer to the manufacturer's diagram for reference A9D11832 to identify terminals and torque values. Do not perform work on a live circuit.

    1. The technician must disconnect all power sources, secure them against reactivation, and verify the absence of voltage with a suitable tool.
    2. Match the device reference, number of poles, current, and voltage with the panel diagram, and review conductor cross-sections and protection coordination.
    3. Mount the device on the rail or its designated position after ensuring compatibility, and identify input and output from the manufacturer's diagram for this reference.
    4. Execute connections using the tightening torque, stripping length, and wire gauges specified in the model manual; do not carry these values over from a similar device.
    5. Check the tightness of the installation and connections, close the covers, and conduct required functional and protection tests before handing over the circuit.

    Frequently Asked Questions Before Buying

    What is the difference between RCBO and RCCB?

    An RCBO combines leakage protection with overcurrent and short-circuit protection, while an RCCB requires separate, coordinated overcurrent protection.

    Does having a leakage breaker eliminate the need for earthing?

    No. Earthing, protective bonding, and coordination of protection devices are independent parts of installation safety and are not eliminated by this breaker.

    Can it be installed in place of any single breaker?

    You must first review dimensions, poles, neutral, connection points, and the panel system. Similarity in width is not sufficient to prove compatibility.

    Order from Bashiti Stores

    Learn more in the Electrical Section and Electrical Breakers category. Bashiti Stores — Yousef Bashiti Company, serving individuals, companies, and projects in Jordan. For inquiries about the product and quantities, contact 0795756898 or visit our Bayader and Wehdat branches in Amman.

    For Comparison Within the Category

    Also check out the Schneider 40A 3P A9S65340 Isolation Switch, and compare the specifications to choose what fits your needs.