Schneider RCCB 25A 2P EZ9R36225 is an option within the earth leakage circuit breakers at Bashiti Stores, designed to monitor residual current and trip the circuit when the specified leakage sensitivity is exceeded. This model has a 25A current rating and 30mA leakage sensitivity. When comparing, distinguish between the current passing through the device and the leakage value that triggers the trip, and review the appropriate protection type for your loads.
Practical Benefits
- Adds earth leakage detection to the protection system when correctly selected and installed.
- The existence of a specific rated current and leakage sensitivity allows for clear comparison between the device and panel requirements.
- Distinguishing between protection type and current helps avoid confusion between wiring protection and leakage protection.
Technical Specifications for this Model
| Brand |
Schneider Electric |
| Series |
Easy9 |
| Model Reference |
EZ9R36225 |
| Rated Current |
25 A |
| Number of Poles |
2P |
| Leakage Sensitivity |
30 mA |
| Leakage Detection Type |
AC |
| Stated Operating Voltage |
230VAC |
| Dimensions: W × H × D |
36 × 82 × 72 mm |
| Mounting |
DIN Rail |
Who Needs This Product?
Technicians preparing and maintaining distribution boards in buildings, when earth leakage protection is required according to the protection plan. The type, sensitivity, current, and number of poles must be selected in coordination with the other circuit breakers and loads.
Installation and Verification Method — For Qualified Technicians
The following steps outline the general workflow; refer to the manufacturer’s schematic for the EZ9R36225 reference to determine terminals and torque values. Do not work on a live circuit.
- The technician disconnects all power sources and secures them against accidental restart, then verifies the absence of voltage with an appropriate tool.
- Matches the device reference, number of poles, current, and voltage with the panel schematic, and reviews conductor cross-sections and protection coordination.
- Mounts the unit on the rail or its designated position after ensuring compatibility, and identifies supply and load connections from the manufacturer’s schematic for this reference.
- Executes the connections using the torque, stripping length, and wire gauges specified in the model manual; do not carry these values over from a similar device.
- Checks the security of the mounting and connections, closes the covers, and performs the required functional and protection tests before handing over the circuit.
FAQs Before Purchasing
Does an RCCB protect against overload and short circuits?
An RCCB does not include overcurrent protection; therefore, it requires coordination with an appropriate circuit breaker or fuse. It is not used as a substitute for overload and short-circuit breakers.
Does 40A mean the leakage sensitivity is 40A?
No. The rated current and leakage sensitivity are two different values; the sensitivity here is stated in milliamperes, while the rated current refers to the current flowing through the device.
Is the AC type suitable for all electronic loads?
Not automatically. The technician determines the required protection type based on the shape of the potential leakage current and the nature of the loads; some circuits may require a different type.
Order from Bashiti Stores
Learn more within the Electrical Department and Circuit Breakers sections. Bashiti Stores — Yousef Bashiti Company, serving individuals, companies, and projects in Jordan. For product and quantity inquiries, contact 0795756898 or visit our Bayader and Wahdat branches in Amman.
For Comparison Within the Category
Also check out the Schneider RCCB 40A 2P EZ9R36240, and compare the specifications to choose what fits your needs.