Schneider RCCB 40A 4P EZ9R36440

Description

Schneider RCCB 40A 4P EZ9R36440 is an option among residual current circuit breakers at Bashiti Stores, designed to detect residual current and disconnect the circuit when the specified leakage sensitivity is exceeded. This model has a 40A current rating and 30mA leakage sensitivity. When comparing, distinguish between the current passing through the device and the leakage value that triggers tripping, and verify the appropriate protection type for your loads.

Practical Benefits

  • Adds residual current detection to the protection system when selected and installed correctly.
  • Having a specific rated current and leakage sensitivity allows for clear comparison of the device against panel requirements.
  • Distinguishing between the protection type and current helps avoid confusion between wiring protection and leakage protection.

Technical Specifications for this Model

Brand Schneider Electric
Series Easy9
Model Reference EZ9R36440
Rated Current 40 A
Number of Poles 4P
Leakage Sensitivity 30 mA
Leakage Detection Type AC
Stated Operating Voltage 400VAC
Dimensions: W x H x D 72 x 82 x 72 mm
Stated Mounting DIN rail

Who needs this product?

Technicians preparing and maintaining distribution boards in buildings when a residual current protection function is required according to the protection plan. The type, sensitivity, current, and number of poles must be selected in coordination with the remaining circuit breakers and loads.

Installation and Verification Method — For Professional Technicians

The following steps outline the general workflow; the manufacturer's diagram for reference EZ9R36440 must be used to identify terminals and torque values. Do not perform work on a live circuit.

  1. The technician disconnects all power sources and secures them against accidental restart, then verifies the absence of voltage with an appropriate tool.
  2. Match the device reference, number of poles, current, and voltage with the panel diagram, and review conductor cross-section and protection coordination.
  3. Mount the unit on the rail or its designated position after ensuring compatibility, and identify the supply and output from the manufacturer's diagram for this reference.
  4. Execute connections with the torque, stripping length, and wire cross-sections specified in the model manual; do not transpose these values from a similar device.
  5. Check the tightness of the installation and connections, then close covers and perform required operational and protection tests before handing over the circuit.

FAQs Before Buying

Does an RCCB protect against overload and short circuits?

An RCCB does not include overcurrent protection, so it requires coordination with an appropriate circuit breaker or fuse. It is not used as a substitute for an overload and short-circuit breaker.

Does 40A mean the leakage sensitivity is 40A?

No. Rated current and leakage sensitivity are two different values; sensitivity here is indicated in milliamperes (mA), while the rated current refers to the current flow capacity of the device.

Is the AC type suitable for all electronic loads?

Not automatically. The technician determines the required protection type based on the shape of the potential leakage current and the nature of the loads; some circuits may require a different type.

Order from Bashiti Stores

Learn more within the Electrical Section and Circuit Breakers category. Bashiti Stores — Yousef Bashiti Company, serving individuals, companies, and projects in Jordan. For inquiries about the product and quantities, contact 0795756898 or visit our Bayader and Wahdat branches in Amman.

For Comparison within the Category

Also check out the Schneider RCCB 63A 4P EZ9R36463, and compare specifications to choose what suits your needs.

Schneider RCCB 40A 4P EZ9R36440

Product form

Schneider RCCB 40A 4P EZ9R36440 is an option among residual current circuit breakers at Bashiti Stores, designed to detect residual... Read more

SKU: 00201663

57.590 JD

    Description

    Schneider RCCB 40A 4P EZ9R36440 is an option among residual current circuit breakers at Bashiti Stores, designed to detect residual current and disconnect the circuit when the specified leakage sensitivity is exceeded. This model has a 40A current rating and 30mA leakage sensitivity. When comparing, distinguish between the current passing through the device and the leakage value that triggers tripping, and verify the appropriate protection type for your loads.

    Practical Benefits

    • Adds residual current detection to the protection system when selected and installed correctly.
    • Having a specific rated current and leakage sensitivity allows for clear comparison of the device against panel requirements.
    • Distinguishing between the protection type and current helps avoid confusion between wiring protection and leakage protection.

    Technical Specifications for this Model

    Brand Schneider Electric
    Series Easy9
    Model Reference EZ9R36440
    Rated Current 40 A
    Number of Poles 4P
    Leakage Sensitivity 30 mA
    Leakage Detection Type AC
    Stated Operating Voltage 400VAC
    Dimensions: W x H x D 72 x 82 x 72 mm
    Stated Mounting DIN rail

    Who needs this product?

    Technicians preparing and maintaining distribution boards in buildings when a residual current protection function is required according to the protection plan. The type, sensitivity, current, and number of poles must be selected in coordination with the remaining circuit breakers and loads.

    Installation and Verification Method — For Professional Technicians

    The following steps outline the general workflow; the manufacturer's diagram for reference EZ9R36440 must be used to identify terminals and torque values. Do not perform work on a live circuit.

    1. The technician disconnects all power sources and secures them against accidental restart, then verifies the absence of voltage with an appropriate tool.
    2. Match the device reference, number of poles, current, and voltage with the panel diagram, and review conductor cross-section and protection coordination.
    3. Mount the unit on the rail or its designated position after ensuring compatibility, and identify the supply and output from the manufacturer's diagram for this reference.
    4. Execute connections with the torque, stripping length, and wire cross-sections specified in the model manual; do not transpose these values from a similar device.
    5. Check the tightness of the installation and connections, then close covers and perform required operational and protection tests before handing over the circuit.

    FAQs Before Buying

    Does an RCCB protect against overload and short circuits?

    An RCCB does not include overcurrent protection, so it requires coordination with an appropriate circuit breaker or fuse. It is not used as a substitute for an overload and short-circuit breaker.

    Does 40A mean the leakage sensitivity is 40A?

    No. Rated current and leakage sensitivity are two different values; sensitivity here is indicated in milliamperes (mA), while the rated current refers to the current flow capacity of the device.

    Is the AC type suitable for all electronic loads?

    Not automatically. The technician determines the required protection type based on the shape of the potential leakage current and the nature of the loads; some circuits may require a different type.

    Order from Bashiti Stores

    Learn more within the Electrical Section and Circuit Breakers category. Bashiti Stores — Yousef Bashiti Company, serving individuals, companies, and projects in Jordan. For inquiries about the product and quantities, contact 0795756898 or visit our Bayader and Wahdat branches in Amman.

    For Comparison within the Category

    Also check out the Schneider RCCB 63A 4P EZ9R36463, and compare specifications to choose what suits your needs.