Schneider MCB 10A 2P R9F32210 is an option among the automatic MCB circuit breakers at Bashiti Stores, designed to protect the circuit from overloads and short circuits. In this option, the rated current is 10 amps and the number of poles is 2P. These specifications distinguish this model from other alternatives in the same series; match them with your circuit requirements and do not choose a breaker with a higher current just to increase the operating margin.
Practical Benefits
- Combines overload and short-circuit tripping functions in a single modular device.
- Distributing protection across independent circuits helps organize the panel and identify the affected circuit in the event of a fault.
- The selection of current, number of poles, and tripping curve provides the basis for matching the breaker to circuit requirements.
Technical Specifications for This Model
| Brand |
Schneider Electric |
| Series |
Resi9 |
Model Reference |
R9F32210 |
| Rated Current |
10 A |
| Number of Poles |
2P |
| Tripping Curve |
C |
| Breaking Capacity per Source Title |
4.5kA |
| Stated Operating Voltage |
400VAC |
| Dimensions: W x H x D |
36 x 81 x 72 mm |
| Stated Mounting |
DIN Rail |
Who Needs This Product?
Electricians, electrical contractors, and homeowners or shop owners setting up a new panel or replacing a breaker that matches an existing circuit. The selection depends on the circuit design, cable cross-section, and routing method, not merely on the device type or the shape of the breaker.
Installation and Verification Method — For Qualified Technicians
The following steps outline the general work sequence; the manufacturer's diagram for reference R9F32210 must be used to identify terminals and tightening values. Do not perform work on a circuit connected to a power source.
- The technician disconnects all power sources, secures them against reactivation, and verifies the absence of voltage using a suitable tool.
- Matches the device reference, number of poles, current, and voltage with the panel diagram, and reviews conductor cross-sections and protection coordination.
- Mounts the unit on the DIN rail or its designated position after ensuring compatibility, and identifies supply and load connections from the manufacturer's diagram for this reference.
- Executes the connections using the tightening torque, stripping length, and wire gauges specified in the model manual; do not carry over these values from a similar device.
- Checks the tightness of the mounting and connections, then closes the covers and performs the required operational and protection tests before handing over the circuit.
--
Frequently Asked Questions Before Purchasing
Does this breaker protect against earth leakage?
An MCB is designed for overloads and short circuits and does not replace earth leakage protection. The need for an RCCB or RCBO should be reviewed within the panel design.
Should I replace a frequently tripping breaker with one that has a higher amperage?
No. You must first identify the cause of the tripping and inspect the load, cable, and connections. Increasing the amperage without study may leave the wires without proper protection.
What is the difference between amperage and breaking capacity?
Amperage is the rated current of the breaker, while breaking capacity describes the level of short-circuit current it can safely interrupt under specified voltage and standard conditions. Neither figure should be replaced by the other.
Order from Bashiti Stores
Learn more in the Electrical Wiring and Electrical Breakers sections. Bashiti Stores — Yousef Bashiti Co., serving individuals, companies, and projects in Jordan. For inquiries regarding the product and quantities, contact us at 0795756898 or visit our Bayader and Al-Wehdat branches in Amman.
For Comparison Within the Category
Also check out the Schneider MCB 16A 2P R9F32216 and compare the specifications to choose what suits your needs.