Schneider MCB 25A 2P R9F32225 is an option within the MCB automatic circuit breaker range at Bashiti Stores, designed to protect circuits from overloads and short circuits. In this model, the rated current is 25 Amps and the number of poles is 2P. These specifications distinguish this model from other alternatives in the same series; match them with your circuit requirements and do not select a breaker with a higher current just to increase the operating margin.
Practical Benefits
- Combines overload and short-circuit protection functions in a single modular device.
- Distributing protection across independent circuits helps organize the panel and identify the affected circuit when a fault occurs.
- Selecting the correct current, number of poles, and tripping curve provides the basis for matching the breaker to the circuit's requirements.
Technical Specifications for this Model
| Brand |
Schneider Electric |
| Series |
Resi9 |
| Model Reference |
R9F32225 |
| Rated Current |
25 A |
| Number of Poles |
2P |
| Tripping Curve |
C |
| Breaking Capacity per Source Title |
4.5kA |
| Stated Operating Voltage |
400VAC |
| Dimensions: W × H × D |
36 × 81 × 72 mm |
| Stated Mounting |
DIN Rail |
Who Needs This Product?
Electricians, installation contractors, and homeowners or shop owners who are setting up a new panel or replacing a breaker that matches an existing circuit. The selection depends on the circuit design, cable cross-section, and installation method, not solely on the type of device or the shape of the breaker.
Installation and Verification Method — For Professional Technicians
The following steps outline the general workflow; the manufacturer's diagram for reference R9F32225 must be followed to determine terminals and torque values. Do not work on a circuit connected to a power supply.
- The technician disconnects all power sources and secures them against accidental reconnection, then verifies the absence of voltage with a suitable tool.
- Matches the device reference, number of poles, current, and voltage with the panel diagram, and reviews conductor cross-sections and protection coordination.
- Installs the unit on the rail or its designated position after ensuring compatibility, and identifies the supply and output from the manufacturer's diagram for this reference.
- Performs the connections according to the torque, stripping length, and wire gauges specified in the model manual; do not carry these values over from a similar device.
- Checks the security of the mounting and connections, then closes the covers and performs the required operational and protection tests before handing over the circuit.
-
Common Questions Before Purchasing
Does this breaker protect against earth leakage?
An MCB is intended for overload and short circuits and does not replace earth leakage protection. Review the need for an RCCB or RCBO within the panel design.
Should I replace a breaker that keeps tripping with one of a higher amperage?
No. You must first determine the cause of the tripping and check the load, cable, and connections. Increasing the amperage without analysis may leave the wires without proper protection.
What is the difference between Amperage and Breaking Capacity?
Amperage is the rated current of the breaker, while breaking capacity describes the level of short-circuit current it can safely disconnect under specified voltage and standard conditions. Neither figure replaces the other.
Order from Bashiti Stores
Learn more in the Electrical Section and Circuit Breakers category. Bashiti Stores — Yousef Bashiti Company, serving individuals, companies, and projects in Jordan. For inquiries about the product and quantities, contact us at 0795756898 or visit our Bayader and Wehdat branches in Amman.
For Comparison Within the Category
Also check out the Schneider MCB 40A 2P R9F32240 and compare the specifications to choose what suits your needs.