Schneider MCB 25A 3P R9F32325 is an option among MCB automatic circuit breakers at Bashiti Stores, designed to protect the circuit against overload and short circuits. In this model, the rated current is 25 amps and the number of poles is 3P. These specifications distinguish this model from other alternatives in the same series; match them with your circuit requirements and do not choose a higher-amperage breaker just to increase the operating margin.
Practical Benefits
- Combines the functions of overload and short-circuit disconnection in a single modular device.
- Distributing protection across independent circuits helps organize the distribution board and identify the affected circuit in the event of a fault.
- Choosing the correct current, number of poles, and tripping curve provides the basis for matching the breaker to circuit requirements.
Technical Specifications for this Model
| Brand |
Schneider Electric |
| Series |
Resi9 |
| Model Reference |
R9F32325 |
| Rated Current |
25 A |
| Number of Poles |
3P |
| Tripping Curve |
C |
| Breaking Capacity per Source Title |
4.5kA |
| Stated Operating Voltage |
400VAC |
| Dimensions: W × H × D |
54 × 81 × 72 mm |
| Stated Mounting |
DIN Rail |
Who needs this product?
Electricians, installation contractors, and homeowners or shop owners who are setting up a new distribution board or replacing a breaker that matches an existing circuit. The choice depends on the circuit design, cable cross-section, and installation method, not just on the type of device or the shape of the breaker alone.
Installation and Verification — For Qualified Technicians
The following steps outline the general workflow. The manufacturer's diagram for reference R9F32325 must be used to determine terminals and torque values. Work must not be performed on a circuit connected to a power supply.
- The technician disconnects all power sources, secures them against reconnection, and verifies the absence of voltage with an appropriate tool.
- Matches the device reference, number of poles, current, and voltage with the board diagram, and reviews conductor cross-section and protection coordination.
- Installs the device on the rail or its designated position after ensuring compatibility, and identifies the supply and load terminals from the manufacturer's diagram for this reference.
- Executes the connections using the tightening torque, stripping length, and wire gauges specified in the model manual; do not carry over these values from a similar device.
- Checks the tightness of the mounting and connections, closes the covers, and performs the required functional and protection tests before handing over the circuit.
FAQs Before Buying
Does this breaker protect against earth leakage?
An MCB is intended for overload and short circuits and does not replace earth leakage protection. The need for an RCCB or RCBO should be reviewed within the distribution board design.
Should I replace a breaker that trips constantly with one with a higher amperage?
No. You must first identify the cause of the tripping and check the load, cable, and connections. Increasing the amperage without analysis may leave the wires without proper protection.
What is the difference between amperage and breaking capacity?
Amperage is the rated current of the breaker, while breaking capacity describes the level of short-circuit current it can disconnect under specified voltage and standard conditions. One figure cannot be replaced by the other.
Order from Bashiti Stores
Learn more within the Electrical Supplies and Circuit Breakers sections. Bashiti Stores — Yousef Bashiti Company, serving individuals, companies, and projects in Jordan. For inquiries about the product and quantities, contact 0795756898 or visit our Bayader and Wahdat branches in Amman.
For Comparison within the Category
Also check out the Schneider MCB 32A 3P R9F32332, and compare specifications to choose what suits your needs.