Schneider RCCB 63A 2P A9R41263

Description

Schneider RCCB 63A 2P A9R41263 is a circuit breaker option within the residual current device category at Bashiti Stores, designed to monitor residual current and disconnect the circuit when the specified leakage sensitivity is exceeded. This model features a 63-amp current rating and 30mA leakage sensitivity. When comparing, distinguish between the current flowing through the device and the leakage value that triggers disconnection, and verify the appropriate protection type for your loads.

Practical Benefits

  • Adds residual current detection functionality to the protection system when selected and installed correctly.
  • The presence of a specific rated current and leakage sensitivity allows for a clear comparison of the device with panel requirements.
  • Distinguishing between protection type and current helps avoid confusion between wiring protection and leakage protection.

Technical Specifications for this Model

Brand Schneider Electric
Series Acti9 iID
Model Reference A9R41263
Rated Current 63 A
Number of Poles 2P
Leakage Sensitivity 30 mA
Leakage Detection Type AC
Stated Operating Voltage 220VAC to 240VAC
Dimensions: W x H x D 36 × 91 × 73.5 mm
Mounting Type DIN rail

Who Needs This Product?

Technicians involved in the assembly and maintenance of distribution panels in buildings, when a residual current protection function is required according to the protection plan. The type, sensitivity, current, and number of poles must be selected in coordination with other circuit breakers and loads.

Installation and Verification Method — For Qualified Technicians

The following steps outline general work procedures; the manufacturer's diagram for reference A9R41263 must be used to identify terminals and connection values. Do not work on a circuit connected to power.

  1. The technician disconnects all power sources and secures them against accidental restart, then verifies the absence of voltage with an appropriate tool.
  2. The device reference, number of poles, current, and voltage are checked against the panel diagram, and conductor cross-section and protection coordination are reviewed.
  3. The component is mounted on the rail or its designated position after ensuring compatibility, and supply/load connections are identified from the manufacturer's diagram for this reference.
  4. Connections are made using the tightening torque, stripping length, and wire gauges specified in the model manual; do not apply values from similar devices.
  5. Installation and connection tightness are inspected, covers are replaced, and required operational and protection tests are performed before handing over the circuit.
  6. -->

Frequently Asked Questions Before Buying

Does an RCCB protect against overload and short circuits?

An RCCB does not include overcurrent protection, so it requires coordination with a suitable circuit breaker or fuse. It is not used as a substitute for an overload and short-circuit breaker.

Does 40 amps mean the leakage sensitivity is 40 amps?

No. Rated current and leakage sensitivity are two different values; the sensitivity here is stated in milliamps, while the rated current refers to the current capacity of the device.

Is the AC type suitable for all electronic loads?

Not automatically. The technician must determine the required type of protection based on the expected leakage current waveform and the nature of the loads; some circuits may require a different type.

Order from Bashiti Stores

Learn more in our Electrical Section and Circuit Breakers category. Bashiti Stores — Yousef Bashiti Company, serving individuals, companies, and projects in Jordan. For inquiries about the product or quantities, contact us at 0795756898 or visit our Bayader and Wehdat branches in Amman.

For Comparison within the Category

Also check out the Schneider RCCB 25A 4P A9R50425 and compare the specifications to choose what suits your needs.

Schneider RCCB 63A 2P A9R41263

Product form

Schneider RCCB 63A 2P A9R41263 is a circuit breaker option within the residual current device category at Bashiti Stores, designed... Read more

SKU: 00201567

63.260 JD

    Description

    Schneider RCCB 63A 2P A9R41263 is a circuit breaker option within the residual current device category at Bashiti Stores, designed to monitor residual current and disconnect the circuit when the specified leakage sensitivity is exceeded. This model features a 63-amp current rating and 30mA leakage sensitivity. When comparing, distinguish between the current flowing through the device and the leakage value that triggers disconnection, and verify the appropriate protection type for your loads.

    Practical Benefits

    • Adds residual current detection functionality to the protection system when selected and installed correctly.
    • The presence of a specific rated current and leakage sensitivity allows for a clear comparison of the device with panel requirements.
    • Distinguishing between protection type and current helps avoid confusion between wiring protection and leakage protection.

    Technical Specifications for this Model

    Brand Schneider Electric
    Series Acti9 iID
    Model Reference A9R41263
    Rated Current 63 A
    Number of Poles 2P
    Leakage Sensitivity 30 mA
    Leakage Detection Type AC
    Stated Operating Voltage 220VAC to 240VAC
    Dimensions: W x H x D 36 × 91 × 73.5 mm
    Mounting Type DIN rail

    Who Needs This Product?

    Technicians involved in the assembly and maintenance of distribution panels in buildings, when a residual current protection function is required according to the protection plan. The type, sensitivity, current, and number of poles must be selected in coordination with other circuit breakers and loads.

    Installation and Verification Method — For Qualified Technicians

    The following steps outline general work procedures; the manufacturer's diagram for reference A9R41263 must be used to identify terminals and connection values. Do not work on a circuit connected to power.

    1. The technician disconnects all power sources and secures them against accidental restart, then verifies the absence of voltage with an appropriate tool.
    2. The device reference, number of poles, current, and voltage are checked against the panel diagram, and conductor cross-section and protection coordination are reviewed.
    3. The component is mounted on the rail or its designated position after ensuring compatibility, and supply/load connections are identified from the manufacturer's diagram for this reference.
    4. Connections are made using the tightening torque, stripping length, and wire gauges specified in the model manual; do not apply values from similar devices.
    5. Installation and connection tightness are inspected, covers are replaced, and required operational and protection tests are performed before handing over the circuit.
    6. -->

    Frequently Asked Questions Before Buying

    Does an RCCB protect against overload and short circuits?

    An RCCB does not include overcurrent protection, so it requires coordination with a suitable circuit breaker or fuse. It is not used as a substitute for an overload and short-circuit breaker.

    Does 40 amps mean the leakage sensitivity is 40 amps?

    No. Rated current and leakage sensitivity are two different values; the sensitivity here is stated in milliamps, while the rated current refers to the current capacity of the device.

    Is the AC type suitable for all electronic loads?

    Not automatically. The technician must determine the required type of protection based on the expected leakage current waveform and the nature of the loads; some circuits may require a different type.

    Order from Bashiti Stores

    Learn more in our Electrical Section and Circuit Breakers category. Bashiti Stores — Yousef Bashiti Company, serving individuals, companies, and projects in Jordan. For inquiries about the product or quantities, contact us at 0795756898 or visit our Bayader and Wehdat branches in Amman.

    For Comparison within the Category

    Also check out the Schneider RCCB 25A 4P A9R50425 and compare the specifications to choose what suits your needs.

    Send us a message!

    Do you want to order the product in bulk for a company?

    Sign up for our newsletter

    Get the best deals

    Don't hesitate to subscribe to receive all offers via email

    © 2026 Bashiti Stores, Powered by Shopify

      Login

      Forgot your password?